DADopamine ELISA Kit - E-EL-0046
Product Details
Properties
Assay type | Competitive-ELISA |
Format | 96T/48T |
Assay time | 2.0h |
Detection range | 31.25-2000 pg/mL |
Sensitivity | 18.75 pg/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 50μL |
Specificity | This kit recognizes DA in samples. No significant cross-reactivity or interference between DA and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of DA concentrations in serum, plasma and other biological fluids. |
Test Principle
Kit components & Storage
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips 48T: 8 wells ×6 strips |
-20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 48T: 1 vial, 60 μL |
-20℃(Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8℃ |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Technical Data
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level DA were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level DA were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 93.20 | 168.70 | 786.20 | 94.20 | 159.90 | 725.00 |
Standard deviation | 6.10 | 7.40 | 29.10 | 5.30 | 9.00 | 37.00 |
CV (%) | 6.55 | 4.39 | 3.70 | 5.63 | 5.63 | 5.10 |
Recovery
The recovery of DA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 95-110 | 101 |
EDTA plasma(n=8) | 97-111 | 102 |
Cell culture media(n=8) | 92-103 | 98 |
Linearity
Samples were spiked with high concentrations of DA and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.


Target Information
Synonyms | 2-(3, 4-dihydroxyphenyl)ethylamine, 3, 4-dihydroxyphenethylamine, 3-hydroxytyramine, DA, Intropin, Revivan, Oxytyramine |
Research Area | Neuroscience |
Assay Procedures
![]() |
1. Add 50μL standard or sample to the wells, immediately add 50μL Biotinylated Detection Ab working solution to each well. Incubate for 45 min at 37°C |
![]() |
2. Aspirate and wash the plate for 3 times |
![]() |
3. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
![]() |
4. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
![]() |
5. Add 50μL Stop Solution |
![]() |
6. Read the plate at 450nm immediately. Calculation of the results |
Citations
-
Science China-Life Sciences (2022) IF: 10.372
Decreased peripheral mtDNA in methamphetamine use disorderSample: blood -
Cell Death & Disease (2022) IF: 8.4689
Combining adoptive NK cell infusion with a dopamine-releasing peptide reduces senescent cells in aged micePMID: 35383143
Sample: plasma